Application of the TEWI Methodology to a Desiccant Cooling System Interacting with a Microcogenerator
PDF

Keywords

Total equivalent warming impact
desiccant cooling system
microcogenerator
electricity production mix
global warming potential.

How to Cite

1.
Angrisani G, Rossi F de, Roselli C, Sasso M. Application of the TEWI Methodology to a Desiccant Cooling System Interacting with a Microcogenerator. Glob. J. Energ. Technol. Res. Updat. [Internet]. 2015 Apr. 1 [cited 2024 Nov. 23];2(1):06-18. Available from: https://avantipublisher.com/index.php/gjetru/article/view/191

Abstract

Desiccant cooling systems, supplied by fossil or renewable fuels, represent a very interesting alternative to conventional electric units based on cooling dehumidification for air conditioning purposes, as they can achieve significant energy and emissions savings. The analysis of environmental impact of energy conversion devices, e.g. in terms of global warming effect, is usually limited to energy-related emissions (indirect contribution), neglecting direct greenhouse gas emissions related to working fluids, such as refrigerants. The Total Equivalent Warming Impact (TEWI) is a more comprehensive methodology, as it takes into account both direct and an indirect contributions to global warming. In this paper, this method is applied to a small scale trigeneration system, in which a microcogenerator, a chiller and a boiler interact with a hybrid desiccant-based cooling system, equipped with a silica-gel desiccant wheel. This trigeneration system is compared with other two systems, in order to assess its potentiality in terms of TEWI reduction. The different direct and indirect contributions of the several equipment are evaluated, and the share of the direct contribution is investigated, considering both the overall TEWI of the complete system, and that of the electric vapour compression device only. Finally, the effect of the greenhouse gas emissions of the electricity production mix and of different values of the Global Warming Potential (GWP) of the refrigerant fluid on the overall TEWI of the three compared systems is investigated.
https://doi.org/10.15377/2409-5818.2015.02.01.2
PDF

References

Fabrizio E, Seguro F, Filippi M. Integrated HVAC and DHW production systems for Zero Energy Buildings. Renew Sust Energ Rev 2014; 40: 515-41. http://dx.doi.org/10.1016/j.rser.2014.07.193

Rosato A, Sibilio S. Performance assessment of a microcogeneration system under realistic operating conditions. Energ Convers Manage 2013; 70: 149-162. http://dx.doi.org/10.1016/j.enconman.2013.03.003

Baniyounes AM, Liu G, Rasul MG, Khan MMK. Analysis of solar desiccant cooling system for an institutional building in subtropical Queensland, Australia. Renew Sust Energ Rev 2012; 16: 6423-31. http://dx.doi.org/10.1016/j.rser.2012.07.021

Calise F, Dentice d’Accadia M, Roselli C, Sasso M, Tariello F. Desiccant-based AHU interacting with a CPVT collector: Simulation of energy and environmental performance. Sol Energy 2014; 103: 574-94. http://dx.doi.org/10.1016/j.solener.2013.11.001

Lee SH, Lee WL. Site verification and modeling of desiccantbased system as an alternative to conventional airconditioning systems for wet markets. Energy 2013; 55: 1076-83. http://dx.doi.org/10.1016/j.energy.2013.04.029

Angrisani G, Minichiello F, Roselli C, Sasso M. Desiccant HVAC system driven by a micro-CHP: Experimental analysis. Energ Build 2010; 42: 2028-35. http://dx.doi.org/10.1016/j.enbuild.2010.06.011

Angrisani G, Minichiello F, Roselli C, Sasso M. Experimental investigation to optimise a desiccant HVAC system coupled to a small size cogenerator. Appl Therm Eng 2011; 31: 506-12. http://dx.doi.org/10.1016/j.applthermaleng.2010.10.006

Angrisani G, Roselli C, Sasso M, Tariello F. Dynamic performance assessment of a micro-trigeneration system with a desiccant-based air handling unit in Southern Italy climatic conditions. Energ Convers Manage 2014; 80: 188-201. http://dx.doi.org/10.1016/j.enconman.2014.01.028

Angrisani G, Roselli C, Sasso M, Tariello F. Assessment of Energy, Environmental and Economic Performance of a Solar Desiccant Cooling System with Different Collector Types. Energies 2014; 7: 6741-64. http://dx.doi.org/10.3390/en7106741

Angrisani G, Roselli C, Sasso M. Experimental assessment of the energy performance of a hybrid desiccant cooling system and comparison with other air-conditioning technologies. Appl Energ 2015; 138: 533-45. http://dx.doi.org/10.1016/j.apenergy.2014.10.065

de Rossi F, Mastrullo R, Sasso M. R502 substitution: a global evaluation of the environmental impact. In: IIR Paris, France, editor. Proceedings of the International Conference on Energy Efficiency in Refrigeration and Global Warming Impact, Commission B1/2 I.I.R. Ghent, Belgium 1993; pp. 335-9.

de Rossi F, Sasso M. An environmental and thermodynamic analysis to select R22 alternative working fluids. Int J Ambient Energy 1995; 16: 76-82. http://dx.doi.org/10.1080/01430750.1995.9675672

Aprea C, Greco A, Maiorino A. The application of a desiccant wheel to increase the energetic performances of a transcritical cycle. Energ Convers Manage 2015; 89: 222- 230. http://dx.doi.org/10.1016/j.enconman.2014.09.066

Technical documentation of chillers from HVAC company RC Group, http://www.rcgroup.it/EN/. (accessed January 05, 2015).

Aprea C, Greco A, Maiorino A. An experimental evaluation of the greenhouse effect in the substitution of R134a with CO2. Energy 2012; 45: 753-761. http://dx.doi.org/10.1016/j.energy.2012.07.015

Benhadid-Dib S, Benzaoui A. Refrigerants and their environmental impact. Substitution of hydro chlorofluorocarbon HCFC and HFC hydro fluorocarbon. Search for an adequate refrigerant. Energy Procedia 2012; 18: 807-16. http://dx.doi.org/10.1016/j.egypro.2012.05.096

Aghahosseini S, Dincer I. Comparative performance analysis of low-temperature Organic Rankine Cycle (ORC) using pure and zeotropic working fluids. Appl Therm Eng 2013; 54: 35-42. http://dx.doi.org/10.1016/j.applthermaleng.2013.01.028

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Copyright (c) 2015 Giovanni Angrisani, Filippo de Rossi, Carlo Roselli, Maurizio Sasso